Railway Cables
Railway Signalling & Control Cables Railway Telecom Cables Railway Power & Control Cables FIRERAIL Traction Cables

 

0.6/1KV Single Core Medium Wall Fire Resistant Traction Cables

 

Application

Single Core power and control cable designed for protected, fixed installation inside and outside railway

vehicles for connecting fi xed and moving parts.

Standards

BS 6853 -1a

DIN 5510-1 1-4

NFF 16-101 F0

BS 6387

Construction

0.6/1KV Single Core Medium Wall Fire Resistant Traction Cables

Conductors

Circular Class 5 stranded plain or tinned copper to BS EN 60228: 2005 / BS 6360.

Flame Barrier

Mica tape.

Insulation

Electron beam crosslinkable medium wall LSZH compound.

Electrical Characteristics at 20℃

Nominal Conductor Cross Section mm² 1.0 1.5 2.5 4.0 6.0 10 16
Maximum Conductor Resistance Ω/km 20.0 13.7 8.21 5.09 3.39 1.95 1.24
Voltage Rating KV 0.6/1.0

 

Nominal Conductor Cross Section mm² 25 35 50 70 95 150
Maximum Conductor Resistance Ω/km 0.795 0.565 0.393 0.277 0.21 0.132
Voltage Rating KV 0.6/1.0

Mechanical and Thermal Properties

Minimum Bending Radius:3×OD (OD<12mm); 4×OD (OD>12mm)

Temperature Range:-40℃ to +120℃

Dimensions And Weight

Cable Code No. of cores& Nominal
Conductor Cross
Sectional Area
No. x AWG
Nominal Diameter
of Strands
No/mm
Nominal Insulation
Thickness
mm
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
FRA-MW-1SU-FR-1G1 1×1.0 32/0.2 0.55 3.15 18.8
FRA-MW-1SU-FR-1G1.5 1×1.5 30/0.25 0.55 3.40 24
FRA-MW-1SU-FR-1G2.5 1×2.5 50/0.25 0.60 4.05 36.6
FRA-MW-1SU-FR-1G4 1×4 56/0.3 0.65 4.60 52.5
FRA-MW-1SU-FR-1G6 1×6 84/0.3 0.70 5.30 73
FRA-MW-1SU-FR-1G10 1×10 80/0.4 0.80 6.35 121
FRA-MW-1SU-FR-1G16 1×16 126/0.4 0.90 8.15 181
FRA-MW-1SU-FR-1G25 1×25 196/0.4 1.00 9.65 261
FRA-MW-1SU-FR-1G35 1×35 276/0.4 1.10 10.80 365
FRA-MW-1SU-FR-1G50 1×50 396/0.41 1.20 12.80 530
FRA-MW-1SU-FR-1G70 1×70 360/0.50 1.30 15.10 730
FRA-MW-1SU-FR-1G95 1×95 475/0.50 1.40 17.00 930
FRA-MW-1SU-FR-1G150 1×150 756/0.50 1.60 21.30 1450